My Account  |  0 item(s)    View Cart
Home > Contactors
12-800VDC 350 Amp
Normally Closed NC
Gigavac Contactor
Contact Voltage 12V, 24V, 48V
ECPC-12-800VDC-350-Amp-NC-Gigavac-Contactor
12-800VDC 350 Amp <br> Normally Closed NC <br> Gigavac Contactor <br> Contact Voltage 12V, 24V, 48V
12-800VDC 350 Amp Normally Closed NC Gigavac Contactor
Email a friend Email a friend
Description

12-800VDC 350 Amp

Normally Closed NC

Gigavac Contactor

Contact Voltage 12V, 24V, 48V


(x6) each 12V Coil in ECPC Stock (no minimum order)


 

FEATURES of the 12-800VDC 350A Normally Closed NC Gigavac Contactor

·        Chassis level power terminals – No need for specially routed power cables, special bus bars, or special lugs.

·        Rugged EPIC seal rated to 347°F (175°C) – Reduced risk of fire or meltdown in over-current conditions. The same technology used for advanced aerospace programs.

·        Hermetically sealed – UL listed: UL1604 for Class I & II, Div 2 and Class III for use in hazardous locations, IP67 for temporary water immersion for 30 min, IP69K for pressure washing, SAE J1171 – external ignition protection, and ISO8846 for protection against ignition around flammable gasses.

·        High Efficiency Dual DC Coils – Very low 12, 24, or 48 VDC continuous coil power with no EMI emissions or crosstalk on your system control power. Ideal for battery powered systems or where low power is needed.

·        Built-in coil suppression for all DC coils – Saves you engineering time and parts cost to add external coil suppression.

·        Stainless steel nuts and mounting inserts, for years of corrosion free service.

·        Not position sensitive – can be mounted in any position for ease of installation.

 

SPECIFICATIONS of the 12-800VDC 350A Gigavac Contactor

 

Contact Type

SPST-NC

Mechanical Life

1,000,000 Cycles

Max Contact Resistance

0.4 mohms

Typical Contact Resistance

0.15 to 0.3 mohms

Max Operate Time

12 ms

Max Release Time

20 ms

Insulation Resistance

100 Mohms

Dielectric at Sea Level

2,200 VRMS

Shock (11ms, ½ sine, peak, operating)

<20g

Vibration Sinusoidal (500-2000 Hz Peak)

15g

Operating Ambient Temperature

-40F to +185F (-55C~+85C)

Storage Ambient Temperature

-40F to +185F (-70C~+150C)

Weight

1.2 Lbs. / 0.5 Kg

Environmental Seal

Exceeds IP67 & IP69K

 

 

COIL RATINGS at (25°C) of the 12-800VDC 350A Gigavac Contactor

 

Nominal Coil Voltage

12 VDC

24 VDC

48 VDC

Max Coil Voltage

16 V

32 V

60 V

Max Pick-Up Voltage

8 V

16 V

32 V

Drop-Out Voltage

0.2 to 4 V

0.5 to 10 V

1 to 20 V

Max Pick-Up Current (75 ms)

4.2 A

1.6 A

0.8 A

Coil Current

0.15 A

0.07 A

0.035 A

Coil Power

1.8 W

1.68 W

1.68 W

Coil Back EMF

55 V

55 V

125 V

Max Transients (13 ms)

50 V

50 V

75 V

Reverse Polarity

16 V

32 V

64 V


Price
Quantity Price
1 - 4 $243.00
5+ $217.00
Price with Options:
$243.00


(Discounts, if applicable, will show in the "Shopping Pallet")

12-800VDC 350 Amp Normally Closed NC Gigavac Contactor Contact Voltage 12V, 24V, 48V
Shipping Method?
Delivery Date Needed? Enter it here:

Special Instructions? Enter them here:

Quantity

 

      

* SHIPPING/PAYMENT OPTIONS *

 

There are 2 ways to get an exact quote for the base shipping for your 12-800VDC 350 Amp Normally Closed NC Gigavac Contactor order.

1.  Contact us at (801) 449-0681 9am-5pm Monday-Friday or email [email protected] or go through our Contact Us page

 

Or

 

2. Place your order by clicking in the shopping pallet “Proceed To Checkout”

a. Enter your information so we can get you a shipping quote

b. Select the “Shipping Method” of preference

c. Confirm the “Choose one payment method” has “Shipping Quote Request” selected

d. Click the “Check Out” button

e. You’ll receive a confirmation email of your request, as will we

 

We’ll research the exact shipping cost and send you an invoice to your PayPal or email or you can add it to your pallet in $1 Shipping Increments for your 12-800VDC 350 Amp Normally Closed NC Gigavac Contactor order.

 

 

Quantity discounts show in the “Shopping Pallet”.

 

We love to meet or beat any competitor’s price!

 

Higher volume discounts, price matching or questions?

Contact Carl, our resident specialist.

9am-9pm Mon-Sat MDT

(801) 449-0681

or email

[email protected]

Or

[email protected]

or through our Contact Us page


Related Items
350 Amp DC Contacts Gigavac Contactor <br> 12V DC Coil Contactor <br> DC or 50/60 Hz AC Contactor <br> 15
350 Amp DC Contacts Gigavac Contactor
12V DC Coil Contactor
DC or 50/60 Hz AC Contactor
15" Leads
<b> SPDT Single Pole Double Throw </b> <br> 400A, 12,000W, 12kW Contactor <br> Mag Blowouts <br> 12V, 24V, 48V, 60V, 72V, or 120V DC Coil <br> EV Contactor Set <br> USA Stock!
SPDT Single Pole Double Throw
400A, 12,000W, 12kW Contactor
Mag Blowouts
12V, 24V, 48V, 60V, 72V, or 120V DC Coil
EV Contactor Set
USA Stock!
<b>DPDT Double Pole Double Throw</b><br>400A Contactor<br>12V, 24V, 48V, 60V, 72V, or 120V DC Coil<br>With Magnetic Blowouts<br>EV Contactor Set
DPDT Double Pole Double Throw
400A Contactor
12V, 24V, 48V, 60V, 72V, or 120V DC Coil
With Magnetic Blowouts
EV Contactor Set
Browse Similar Items
Wiring Components