My Account  |  0 item(s)    View Cart
Home > Contactors
200A, 12,000W, 12kW Contactor
Mag Blowouts
12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil
SPST or SPDT
Max DC Contact Voltages/Amperages
12V 1000A---24V 500A
48V 250A---72V 160A
96V 125A---120V 100A
144V 80A---300V 40A
USA Stock!
ECPC-200D-Contactor
200A, 12,000W, 12kW Contactor<br>Mag Blowouts<br>12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil<br>SPST or SPDT<br>Max DC Contact Voltages/Amperages<br>12V 1000A---24V 500A<br>48V 250A---72V 160A<br>96V 125A---120V 100A<br>144V 80A---300V 40A<br>USA Stock!
200A 12,000W, 12kW Contactor 12V-1000A, 24V-500A, 48V-250A, 72V-160A, 96V-125A, 120V-100A, 144V-80A, 300V-40A, 12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil NO-Normally Open EV Contactor Set
Email a friend Email a friend
Description

200A, 12,000W, 12kW Contactor

12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil

Single Pole Single Throw (SPST) or

Single Pole Double Throw (SPDT)

With Magnetic Blowouts

Max DC Contact Voltages and Amperages

12V 1000A---24V 500A

48V 250A---72V 160A

96V 125A---120V 100A

144V 80A---300V 40A

12V, 24V, or 48VDC Coil USA Stock!


5 each 12V in USA Stock (no minimum order)

19 each 24V in USA Stock (no minimum order)

0 each 48V in USA Stock (no minimum order)

 

This contactor is the standard of the EV industry. Your 200A 12,000W, 12kW contactor comes with a 12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil. A bracket and screws are included with the contactor. Multiples of this contactor can be used in series for higher voltage battery packs. Always ensure that the products you use are within their ratings.


FEATURES for your 200A 12,000W, 12kW EV Contactor Set

o 200A Contact Switching

o SPST-NO Contact

o Maximum Coil Energy Waste: 15W

o 1.5A Power Draw

o To confirm the contact will work for your needs, multiply the contact current rating below (100A) by the contact rating voltage below, (60 for DC) and you get the max wattage of the contactor (6000W, 6kW)

§ then divide the wattage by your expected maximum voltage, example: 144V (6000/144=41.6)

§ And you get the max amperage of 41.6A

§ You will need to stay under the max Wattage of 6000 at all times in order to keep your contactor safe


SPECIFICATIONS for your 200A 12,000W, 12kW EV Contactor Set

Contact

1H (SPST-NO)

Contact Material

AgCdO(12)

Contact Rating(at Resistive Load)

200A 60VDC

200A 240VAC

Max. Switching Voltage

60VDC,240VAC

Max. Switching Power

50,000VA

Endurance of Over Load Current(7Ie/10S)

1400A/10S

Coil Rated Voltages Available

12,24,48,60,72,96,120 VDC

Pick-up Voltage

(40~70) % of coil rated voltage

Drop-out Voltage

(5~30) % of coil rated voltage

Contact Pressure Drop

At most 30mv when 100A

Insulation Resistance

Min. 100 Milliohms at 500VDC

Dielectric Strength

(Between Insulated Electric Parts)

1000VAC 50 HZ/60 HZ (1 minute)

Operate Time

Max. 50mSec.

Release Time

Max. 50mSec.

Ambient Temperature

-13F~+104F (-25C~+40C)

The shocking of fixed point

(10~200)HZ,Acceleration <3.5g

Shocking

(60~100) time/minute,Acceleration <4g

Mechanical Life

100,000 Operations (no load)

Electrical Life

50,000 Operations (at rated load)

Relative Humidity

Up to 98% at +68F (+20C)

Mounting Directions

Can be mounted vertically or horizontally, if mounted vertically the coil should be at the bottom


Price
Quantity Price
1 $48.00
2 - 5 $45.60
6 - 10 $43.20
11 - 20 $42.24
21 - 49 $41.28
50+ $37.44
Price with Options:
$48.00


(Discounts, if applicable, will show in the "Shopping Pallet")

200A 12,000W, 12kW 12V-1000A, 24V-500A, 48V-250A, 72V-160A, 96V-125A, 120V-100A, 144V-80A, 300V-40A, 12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil EV Contactor Set
Contactor Coil Voltage Needed?
Single Pole Single Throw or Single Pole Double Throw?
Single Pole Single Throw (+$0)
12V Single Pole Double Throw (+$26)
Stock/Production Option?
USA Current Stock 12V, 24V, or 48VDC Coil
China Stock/Production (-$6)
Shipping Method?
Delivery Date Needed? Enter it here:

Special Instructions? Enter them here:

Quantity




* SHIPPING/PAYMENT OPTIONS *


There are 2 ways to get an exact quote for the base shipping for your 200A 12,000W, 12kW 12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil EV Contactor order.

1. Contact us at (801) 449-0681 9am-5pm Monday-Friday or email [email protected] or go through our Contact Us page

Or

2. Place your order by clicking in the shopping pallet “Proceed To Checkout”

a. Enter your information so we can get you a shipping quote

b. Select the “Shipping Method” of preference

c. Confirm the “Choose one payment method” has “Shipping Quote Request” selected

d. Click the “Check Out” button

e. You’ll receive a confirmation email of your request, as will we

We’ll research the exact shipping cost and send you an invoice to your PayPal or email or you can add it to your pallet in $1 Shipping Increments for your 200A 12,000W, 12kW 12V, 24V, 48V, 60V, 72V, 96V or 120V DC Coil EV Contactor order.


Quantity discounts show in the “Shopping Pallet”.


We love to meet or beat any competitor’s price!


Higher volume discounts, price matching or questions?

Contact Carl, our resident specialist.

9am-9pm Mon-Sat MDT

(801) 449-0681

or email

[email protected]tsCompany.com

Or

[email protected]

or through our Contact Us page


Related Items
<b>SPDT Single Pole Double Throw</b><br>200A, 12,000W, 12kW Contactor<br>With Magnetic Blowouts<br>12V DC Coil<br>Max DC Contact Voltages/Amperages<br>12V 1000A---24V 500A<br>48V 250A---72V 160A<br>96V 125A---120V 100A<br>144V 80A---300V 40A<br>USA Stock!
SPDT Single Pole Double Throw
200A, 12,000W, 12kW Contactor
With Magnetic Blowouts
12V DC Coil
Max DC Contact Voltages/Amperages
12V 1000A---24V 500A
48V 250A---72V 160A
96V 125A---120V 100A
144V 80A---300V 40A
USA Stock!
Single Pole Single Throw (SPST) <br> 200 AMP Contacts <br> 12 Volt-900 Volt <br> with 9 Volt-36 Volt DC Coil <br> This contactor only takes 0.15 amps to hold the contacts <br> closed while more conventional contactors take >1.2 amps
Single Pole Single Throw (SPST)
200 AMP Contacts
12 Volt-900 Volt
with 9 Volt-36 Volt DC Coil
This contactor only takes 0.15 amps to hold the contacts
closed while more conventional contactors take >1.2 amps
<b>DPDT Double Pole Double Throw</b><br>400A Contactor<br>12V, 24V, 48V, 60V, 72V, or 120V DC Coil<br>With Magnetic Blowouts<br>EV Contactor Set
DPDT Double Pole Double Throw
400A Contactor
12V, 24V, 48V, 60V, 72V, or 120V DC Coil
With Magnetic Blowouts
EV Contactor Set