75V-90V-109V
40Ah 3kW-4kW
2C-3C EV-Hybrid
Battery Pack
UL, CE, SGS-RoHS,
RBRC, ISO, and TS Certified
Custom Lithium LiFePO4
Cylindrical Battery Pack
Custom Built
Cylindrical Li-Ion LiPo Battery Pack
Comes with an Advanced BMS
pre-installed!
·
4.3 Inch (109mm) LCD screen display
o Can be built-in or be sent separately to be
installed in the dashboard
·
Cooling fan
·
DC/DC inverter
·
Max Continuous discharge amperage is 2C
·
Max Peak discharge amperage is 3C for 1~10 seconds
Optional Charger
·
Vented
·
109.5V, 8A peak output
·
Will charger your pack in around 3 ½ hours
Your 75V-90V-109V 40Ah
3kW-4kW 2C-3C EV-Hybrid Lithium LiFePO4 Li-Ion LiPo Custom Built Rechargeable
UL, CE, SGS-RoHS, RBRC, ISO and TS Certified Cylindrical Battery Pack combines
cylindrical cells for higher voltage and capacity applications than those of a
single cell. This permits your 75V-90V-109V 40Ah 3kW-4kW 2C-3C EV-Hybrid Lithium
LiFePO4 Li-Ion LiPo Custom Built Rechargeable UL, CE, SGS-RoHS, RBRC, ISO and
TS Certified Cylindrical Battery Pack to have all the advantages
of cylindrical cells with a voltage and capacity suitable for large scale applications.
If needed, we can special order a custom built pack to your specifications just
give us a call at (801) 449-0681 or email info@electriccarpartscompany.com
Ah
|
40 (0.2C5A)
|
MAX CONTINUOUS DISCHARGE AMPERAGE
|
2 C5A
– 80Ah
|
MAX PEAK DISCHARGE AMPERAGE
|
3 C5A
– 120Ah
|
STANDARD CHARGE
|
0.2C-8A
|
FAST CHARGE
|
1C-40A
|
DISCHARGE CUT-OFF VOLTAGE (2.5V per
cell series)
|
75V
|
BASE VOLTAGE (3V)
|
90V – 3.6kW
|
CHARGE CUT-OFF VOLTAGE (3.65V)
|
109.5V – 4.38kW
|
SERIES / PARALLEL / CELL COUNT
|
30 / 8 / 240
|
DIMENSIONS
|
32*12*7 in (812 * 304 *
177 mm)
|
WEIGHT
|
122 lbs (55 kgs) total
|
CYCLE LIFE (80% DOD)
(Based on 1C Discharge and Charge)
|
2000
|
SELF DISCHARGE RATE (30 DAYS)
|
3%
|
OPERATING TEMP
|
-4 to 113F (-20 to 45C)
|
CHARGING TEMP
|
32 to 113F (0 to 45C)
|
STORAGE TEMP
|
-4 to 150F (-20 to 75C)
|
IMPEDANCE (MAX, AT 1000HZ)
|
= 25 m O
|
ENERGY TYPE
|
75V-90V-109V 40Ah 3kW-4kW 2C-3C EV-Hybrid Lithium LiFePO4
Custom Built Cylindrical Battery Pack
|
Storage and Transportation
requirements
Your 75V-90V-109V 40Ah
3kW-4kW 2C-3C EV-Hybrid Lithium LiFePO4 Li-Ion LiPo Custom Built Rechargeable UL,
CE, SGS-RoHS, RBRC, ISO and TS Certified Cylindrical Battery Pack should be
transported at a 50% charge. Ensure that the contacts are not shorted and that
the battery pack is not immersed in or exposed to any liquid. The battery
should always be between -4°F and 113°F (-20°C and 45°C). The 75V-90V-109V 40Ah 3kW-4kW 2C-3C EV-Hybrid
Lithium LiFePO4 Li-Ion LiPo Custom Built Rechargeable UL, CE, SGS-RoHS, RBRC,
ISO and TS Certified Cylindrical Battery Pack should be kept upright. Do
not drop the pack or stack things on top of it.
Safety information
·
Avoid overcharging or over-discharging your 75V-90V-109V 40Ah 3kW-4kW
2C-3C EV-Hybrid Lithium LiFePO4 Li-Ion LiPo Custom Built Rechargeable UL, CE,
SGS-RoHS, RBRC, ISO and TS Certified Cylindrical Battery Pack. Lithium batteries are sensitive to being overcharged or overly
discharged. Overcharging or over-discharging lithium cells may lead to a much
shorter cycle lifetime.
·
Do not immerse lithium batteries in
water or allow them to get wet for any prolong period of time.
·
If a battery cell smells bad, is very
hot, or appears deformed, remove it from the system and your 75V-90V-109V 40Ah
3kW-4kW 2C-3C EV-Hybrid Lithium LiFePO4 Li-Ion LiPo Custom Built Rechargeable
UL, CE, SGS-RoHS, RBRC, ISO and TS Certified Cylindrical Battery Pack. If the battery is under manufacturer’s warranty take a picture of
the battery as soon as possible.
·
In the event of a cracked or
physically damaged battery cell, do not allow any lithium battery electrolyte
to come in contact with your skin. If you do come in physical contact
with the lithium electrolyte wash the exposed area with clean soapy water as
soon as possible.
·
To avoid electrical shorts, do not
ship or store any metal objects near your 75V-90V-109V 40Ah 3kW-4kW 2C-3C EV-Hybrid Lithium
LiFePO4 Li-Ion LiPo Custom Built Rechargeable UL, CE, SGS-RoHS, RBRC, ISO and
TS Certified Cylindrical Battery Pack.
·
Do not incinerate or expose lithium
batteries to a fire or high heat source.
·
Store lithium batteries at 50% SOC,
(State of Charge). Check and recharge every 6 months.
·
Check the voltage of the battery pack
before connecting your 75V-90V-109V 40Ah
3kW-4kW 2C-3C EV-Hybrid Lithium LiFePO4 Li-Ion LiPo Custom Built Rechargeable
UL, CE, SGS-RoHS, RBRC, ISO and TS Certified Cylindrical Battery Pack to ensure that it is within the safe range. Inspect the BMS for damage
before charging the pack.
·
Clean any dirty electrodes or
components with a dry cloth.
·
To avoid possible electrocution,
always use caution when working with your battery pack or the BMS
system. Wear rubber gloves and have a professional
licensed electrician to assist you when working with your 75V-90V-109V 40Ah 3kW-4kW 2C-3C
EV-Hybrid Lithium LiFePO4 Li-Ion LiPo Custom Built Rechargeable UL, CE,
SGS-RoHS, RBRC, ISO and TS Certified Cylindrical Battery Pack.
|