Classic Style
Gauge Panel
600A Ammeter
Gauge Panel Comes With:
1ea 0-600A Ammeter Input - 0-50 mv
IMPORTANT!
For lighting, order light kit # 186
To prevent damage to instrument, do not
connect AMP to any other power source than the shunt.
If no reading: Check all connections.
If amp reading is reversed, then reverse
pin #1 and #3 connections.
Install the instrument in a 2-1/16 hole,
in convenient operating place. Use U clamp to hold in place.
Install the amp shunt between the positive
battery and the load system.
On the rear of the instrument there are
connecting pins with corresponding numbers.
Use patch cable provided to connect the
instrument to the appropriate shunt. See illustration.
Connect pin #1 to the white shunt lead.
Connect pin #3 to the black shunt lead. See illustration.
Patch cable may be shortened or lengthened
without affecting accuracy of unit. Using 20-22 gauge stranded wire is
recommended.
|